1. To turn out bolts of 3 fastenings of a reception pipe to the final pipeline.
2. To unscrew nuts of bolts of the 7th fastening of converter.
3. To remove a reception pipe and converter.
4. To take out old consolidation 1.
To clear
PERFORMANCE ORDER
Condensed surfaces of a flange and the final pipeline.
To establish or attach
PERFORMANCE ORDER
1. New consolidation 1.
2. Reception pipe and converter.
3. Fixing bolts and converter nuts.
4. Fixing bolts of a reception pipe. To tighten bolts of fastening of a reception pipe to the final pipeline the moment of 20 Nanometers. To tighten nuts and bolts of fastening of converter to a reception pipe the moment of 20 Nanometers.