Deu Neksiya + Maintenance instruction + Maintenance + Engine + 3. Engine (two top camshafts) + cooling System + Toplevnaya and exhaust systems - Electric chain 6.2. General description 6.3. Rules of care of the accumulator 6.4. Accumulator check 6.5. Battery charging 6.6. Storage battery 6.7. System of start-up of the engine 6.8. Diagnostics of malfunctions 6.9. Algorithm of diagnostics of malfunctions 6.10. Traction relay 6.11. Coupling of a free wheeling (MCX) 6.12. Repair of knots of a starter of 5MT and 10МТ 6.13. Generator 6.14. Diagnostics of malfunctions of the CS-121 generator 6.15. Generator dismantle 6.16. CS-130 generator repair + 7. Ignition system + 8. Electronic control unit and sensors + Transmission + 10. Five-speed transmission and main RPO MM5 broadcast + 11. Automatic Transmission + Steering + Running gear + 14. Forward suspension bracket + 15. Drive of forward wheels + 16. Back suspension bracket + Brake system + Body + Heating, ventilation + Electric equipment
|
CS-121 and CS-130 generators enter into a series of Delco Remy CS generators. Figures in designations correspond to external diameter (in mm) a stator. In generators of the CS series the new type of regulators of tension on three diodes is used. The phase windings of a stator connected on the scheme "triangle", the vypryamitelny block, a rotor with contact rings and brushes have a traditional design. On a shaft of the generator the pulley with a krylchatka for обдува the generator is established. The viewing opening is absent. The starter at refusal is not subject to repair and is replaced assembled. |
|